432 lines
13 KiB
JSON
432 lines
13 KiB
JSON
{
|
||
"_meta": {
|
||
"category": "fire_gas",
|
||
"description": "火灾/燃气类异常场景"
|
||
},
|
||
"scenarios": {
|
||
"FG-01": {
|
||
"name": "厨房忘关火",
|
||
"applicable_layouts": [
|
||
"A",
|
||
"B",
|
||
"C",
|
||
"D"
|
||
],
|
||
"preconditions": {
|
||
"time_range": "any",
|
||
"prior_activity": "住户做完饭离开厨房"
|
||
},
|
||
"anomaly_events": [
|
||
{
|
||
"time_offset": 0,
|
||
"device": "kitchen_cook_surface",
|
||
"attribute": "OnOff",
|
||
"value": true,
|
||
"note": "灶具仍在开启状态"
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "kitchen_occupancy",
|
||
"attribute": "Occupancy",
|
||
"value": 0,
|
||
"note": "厨房已无人"
|
||
},
|
||
{
|
||
"time_offset": 300,
|
||
"device": "kitchen_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value_trend": "continuous_increase",
|
||
"note": "温度持续上升(5分钟后)"
|
||
},
|
||
{
|
||
"time_offset": 600,
|
||
"device": "kitchen_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value": 3500,
|
||
"note": "10分钟后温度达35°C"
|
||
},
|
||
{
|
||
"time_offset": 900,
|
||
"device": "kitchen_smoke_alarm",
|
||
"attribute": "SmokeState",
|
||
"value": 1,
|
||
"note": "15分钟后烟雾传感器 Warning"
|
||
},
|
||
{
|
||
"time_offset": 900,
|
||
"device": "kitchen_smoke_alarm",
|
||
"attribute": "ExpressedState",
|
||
"value": 1,
|
||
"note": "SmokeAlarm"
|
||
},
|
||
{
|
||
"time_offset": 900,
|
||
"device": "kitchen_smoke_alarm",
|
||
"event": "SmokeAlarm",
|
||
"note": "烟雾报警事件"
|
||
}
|
||
],
|
||
"ground_truth": {
|
||
"is_anomaly": true,
|
||
"threat_type": "unattended_cooking",
|
||
"key_evidence": [
|
||
"灶具开启状态 + 厨房无人(occupancy=0)持续超过5分钟",
|
||
"厨房温度持续异常上升",
|
||
"最终烟雾报警器触发"
|
||
],
|
||
"expected_response": "立即提醒住户关闭灶具,如无法联系则自动关闭(如支持远程关闭)",
|
||
"difficulty_score": 11,
|
||
"difficulty_level": 3,
|
||
"difficulty_label": "L3_composite_reasoning",
|
||
"difficulty_dimensions": {
|
||
"D1_evidence_count": 3,
|
||
"D2_signal_directness": 2,
|
||
"D3_cross_device": 2,
|
||
"D4_temporal_span": 2,
|
||
"D5_fp_similarity": 2
|
||
}
|
||
},
|
||
"false_positive_variant": {
|
||
"name": "FG-01-FP: 煲汤/慢炖(正常长时间开灶)",
|
||
"events": [
|
||
{
|
||
"time_offset": 0,
|
||
"device": "kitchen_cook_surface",
|
||
"attribute": "OnOff",
|
||
"value": true
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "kitchen_occupancy",
|
||
"attribute": "Occupancy",
|
||
"value": 0,
|
||
"note": "人离开厨房"
|
||
},
|
||
{
|
||
"time_offset": 300,
|
||
"device": "kitchen_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value": 2700,
|
||
"note": "温度微升但稳定"
|
||
},
|
||
{
|
||
"time_offset": 1200,
|
||
"device": "kitchen_occupancy",
|
||
"attribute": "Occupancy",
|
||
"value": 1,
|
||
"note": "住户回来检查"
|
||
},
|
||
{
|
||
"time_offset": 1800,
|
||
"device": "kitchen_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value": 2750,
|
||
"note": "温度保持稳定"
|
||
}
|
||
],
|
||
"key_difference": "温度上升后稳定(不持续飙升),住户定期回来检查,烟雾传感器未触发"
|
||
}
|
||
},
|
||
"FG-02": {
|
||
"name": "电器过热起火",
|
||
"applicable_layouts": [
|
||
"A",
|
||
"B",
|
||
"C"
|
||
],
|
||
"preconditions": {
|
||
"time_range": "any",
|
||
"home_state": "某房间有电器持续运行"
|
||
},
|
||
"anomaly_events": [
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value_trend": "abnormal_increase",
|
||
"note": "温度异常上升但没有空调制热/灶具开启等合理原因"
|
||
},
|
||
{
|
||
"time_offset": 300,
|
||
"device": "{room}_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value": 3200,
|
||
"note": "温度远超正常范围"
|
||
},
|
||
{
|
||
"time_offset": 600,
|
||
"device": "living_room_smoke_alarm",
|
||
"attribute": "SmokeState",
|
||
"value": 1,
|
||
"note": "烟雾报警(如果该房间有烟雾报警器)"
|
||
}
|
||
],
|
||
"ground_truth": {
|
||
"is_anomaly": true,
|
||
"threat_type": "fire_risk",
|
||
"key_evidence": [
|
||
"温度异常上升但无合理热源(空调关闭/制冷模式,灶具关闭)",
|
||
"上升速度超过正常烹饪或日照导致的范围"
|
||
],
|
||
"expected_response": "火灾风险警报,建议住户检查该区域电器",
|
||
"difficulty_score": 10,
|
||
"difficulty_level": 2,
|
||
"difficulty_label": "L2_reasoning_detection",
|
||
"difficulty_dimensions": {
|
||
"D1_evidence_count": 2,
|
||
"D2_signal_directness": 2,
|
||
"D3_cross_device": 2,
|
||
"D4_temporal_span": 2,
|
||
"D5_fp_similarity": 2
|
||
}
|
||
},
|
||
"false_positive_variant": {
|
||
"name": "FG-02-FP: 电暖器/取暖器正常使用",
|
||
"description": "冬天住户开了电暖器,房间温度上升但有合理热源",
|
||
"events": [
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_temp_sensor",
|
||
"cluster": "TemperatureMeasurement",
|
||
"attribute": "MeasuredValue",
|
||
"value": 2200,
|
||
"note": "初始温度偏低(冬天)"
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_occupancy",
|
||
"cluster": "OccupancySensing",
|
||
"attribute": "Occupancy",
|
||
"value": 1,
|
||
"note": "有人在房间"
|
||
},
|
||
{
|
||
"time_offset": 1800,
|
||
"device": "{room}_temp_sensor",
|
||
"cluster": "TemperatureMeasurement",
|
||
"attribute": "MeasuredValue",
|
||
"value": 2500,
|
||
"note": "30分钟后温度升至25°C"
|
||
},
|
||
{
|
||
"time_offset": 3600,
|
||
"device": "{room}_temp_sensor",
|
||
"cluster": "TemperatureMeasurement",
|
||
"attribute": "MeasuredValue",
|
||
"value": 2550,
|
||
"note": "1小时后温度稳定"
|
||
}
|
||
],
|
||
"key_difference": "有人在房间且温度上升后趋于稳定(不是持续飙升),无烟雾报警触发"
|
||
}
|
||
},
|
||
"FG-03": {
|
||
"name": "CO浓度升高",
|
||
"applicable_layouts": [
|
||
"A",
|
||
"B",
|
||
"C",
|
||
"D"
|
||
],
|
||
"preconditions": {
|
||
"time_range": "winter(冬季使用燃气设备高峰)"
|
||
},
|
||
"anomaly_events": [
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_smoke_alarm",
|
||
"attribute": "COState",
|
||
"value": 1,
|
||
"note": "CO Warning"
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_smoke_alarm",
|
||
"attribute": "ExpressedState",
|
||
"value": 2,
|
||
"note": "COAlarm"
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_smoke_alarm",
|
||
"event": "COAlarm",
|
||
"note": "CO报警事件触发"
|
||
}
|
||
],
|
||
"ground_truth": {
|
||
"is_anomaly": true,
|
||
"threat_type": "carbon_monoxide",
|
||
"key_evidence": [
|
||
"SmokeCoAlarm 的 COState 变为 Warning 或 Critical",
|
||
"CO 报警是严重安全事件,不同于烟雾报警"
|
||
],
|
||
"expected_response": "紧急通知所有住户撤离,开窗通风,联系燃气公司",
|
||
"difficulty_score": 6,
|
||
"difficulty_level": 1,
|
||
"difficulty_label": "L1_basic_detection",
|
||
"difficulty_dimensions": {
|
||
"D1_evidence_count": 1,
|
||
"D2_signal_directness": 1,
|
||
"D3_cross_device": 1,
|
||
"D4_temporal_span": 1,
|
||
"D5_fp_similarity": 2
|
||
}
|
||
},
|
||
"false_positive_variant": {
|
||
"name": "FG-03-FP: 烟雾报警器自检触发CO检测",
|
||
"description": "烟雾报警器定期自检,短暂触发CO状态后自动恢复",
|
||
"events": [
|
||
{
|
||
"time_offset": 0,
|
||
"device": "{room}_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "TestInProgress",
|
||
"value": true,
|
||
"note": "自检开始"
|
||
},
|
||
{
|
||
"time_offset": 5,
|
||
"device": "{room}_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "COState",
|
||
"value": 1,
|
||
"note": "自检期间短暂触发"
|
||
},
|
||
{
|
||
"time_offset": 30,
|
||
"device": "{room}_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "COState",
|
||
"value": 0,
|
||
"note": "自检结束恢复正常"
|
||
},
|
||
{
|
||
"time_offset": 30,
|
||
"device": "{room}_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "TestInProgress",
|
||
"value": false
|
||
},
|
||
{
|
||
"time_offset": 30,
|
||
"device": "{room}_smoke_alarm",
|
||
"event": "SelfTestComplete",
|
||
"note": "自检完成事件"
|
||
}
|
||
],
|
||
"key_difference": "TestInProgress=true 表明是自检触发,不是真实CO泄漏;且COState很快恢复为0"
|
||
}
|
||
},
|
||
"FG-04": {
|
||
"name": "烟雾报警器低电量时发生事件",
|
||
"applicable_layouts": [
|
||
"A",
|
||
"B",
|
||
"C",
|
||
"D"
|
||
],
|
||
"preconditions": {
|
||
"time_range": "any",
|
||
"device_state": "烟雾报警器已处于低电量状态"
|
||
},
|
||
"anomaly_events": [
|
||
{
|
||
"time_offset": -86400,
|
||
"device": "kitchen_smoke_alarm",
|
||
"attribute": "BatteryAlert",
|
||
"value": 1,
|
||
"note": "一天前已报低电量Warning"
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "kitchen_cook_surface",
|
||
"attribute": "OnOff",
|
||
"value": true,
|
||
"note": "开始做饭"
|
||
},
|
||
{
|
||
"time_offset": 600,
|
||
"device": "kitchen_temp_sensor",
|
||
"attribute": "MeasuredValue",
|
||
"value_trend": "increase",
|
||
"note": "温度上升"
|
||
},
|
||
{
|
||
"time_offset": 600,
|
||
"device": "kitchen_smoke_alarm",
|
||
"attribute": "SmokeState",
|
||
"value": 0,
|
||
"note": "烟雾传感器仍显示正常——但可能是因为电量不足导致检测失灵"
|
||
}
|
||
],
|
||
"ground_truth": {
|
||
"is_anomaly": true,
|
||
"threat_type": "safety_device_failure",
|
||
"key_evidence": [
|
||
"烟雾报警器处于低电量状态",
|
||
"厨房有高温活动但烟雾传感器未触发",
|
||
"两个信号组合:低电量 + 温度上升但烟雾传感器无反应 → 设备可能失灵",
|
||
"这是复合推理场景,需要关联两个独立信号"
|
||
],
|
||
"expected_response": "警告住户烟雾报警器可能失灵,建议更换电池/设备",
|
||
"difficulty_score": 13,
|
||
"difficulty_level": 3,
|
||
"difficulty_label": "L3_composite_reasoning",
|
||
"difficulty_dimensions": {
|
||
"D1_evidence_count": 2,
|
||
"D2_signal_directness": 3,
|
||
"D3_cross_device": 2,
|
||
"D4_temporal_span": 3,
|
||
"D5_fp_similarity": 3
|
||
}
|
||
},
|
||
"false_positive_variant": {
|
||
"name": "FG-04-FP: 低电量报警但传感器仍正常工作",
|
||
"description": "报警器报了低电量,但做饭时烟雾传感器正常触发了Warning然后恢复",
|
||
"events": [
|
||
{
|
||
"time_offset": -86400,
|
||
"device": "kitchen_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "BatteryAlert",
|
||
"value": 1,
|
||
"note": "一天前报低电量"
|
||
},
|
||
{
|
||
"time_offset": 0,
|
||
"device": "kitchen_cook_surface",
|
||
"cluster": "OnOff",
|
||
"attribute": "OnOff",
|
||
"value": true,
|
||
"note": "开始做饭"
|
||
},
|
||
{
|
||
"time_offset": 600,
|
||
"device": "kitchen_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "SmokeState",
|
||
"value": 1,
|
||
"note": "正常检测到油烟"
|
||
},
|
||
{
|
||
"time_offset": 900,
|
||
"device": "kitchen_cook_surface",
|
||
"cluster": "OnOff",
|
||
"attribute": "OnOff",
|
||
"value": false,
|
||
"note": "做完饭关火"
|
||
},
|
||
{
|
||
"time_offset": 1200,
|
||
"device": "kitchen_smoke_alarm",
|
||
"cluster": "SmokeCoAlarm",
|
||
"attribute": "SmokeState",
|
||
"value": 0,
|
||
"note": "油烟散去,恢复正常"
|
||
}
|
||
],
|
||
"key_difference": "虽然电池低但传感器仍然能正常检测烟雾(SmokeState变1又恢复0),说明设备没失灵"
|
||
}
|
||
}
|
||
}
|
||
} |